FREEMODBUS 1.5 ATSAM3S EXAMPLE
|
|
==============================
|
|
|
|
REQUIREMENTS
|
|
============
|
|
|
|
This example contains a simple demo program for FreeMODBUS for the AT91SAM3S
|
|
Cortex M3 controllers on the SAM3S-EK [0] evaluation kit. It requires a wired
|
|
RS485 connection to a host processor and a MODBUS master software on the PC
|
|
side to be useful. Demo versions of MODBUS master stacks can be found in
|
|
[1], [2] and [3]. Commercial MODBUS stacks are available from [4].
|
|
|
|
INSTALLATION
|
|
============
|
|
The SAM3S-EK evaluation board should be modified as following to enable RS485
|
|
data transmission.
|
|
|
|
- Place Jumpers JP11, JP10 and JP12
|
|
- Place a solder drop accross R25
|
|
|
|
Warning: The RS485 shares data lines with USART1. It is therefore absolutely
|
|
necessary to set PA23 to a high level.
|
|
|
|
SOURCE
|
|
======
|
|
|
|
TESTING
|
|
=======
|
|
|
|
Start the MODBUS sample application and test if the input registers starting
|
|
at protocol address 1000 can be read. There are four registers values avai-
|
|
lable and the output should look like:
|
|
|
|
Polling slave (Ctrl-C to stop) ...
|
|
[1000]: 6474
|
|
[1001]: 0
|
|
[1002]: 0
|
|
[1003]: 0
|
|
Polling slave (Ctrl-C to stop) ...
|
|
[1000]: -8831
|
|
[1001]: 0
|
|
[1002]: 0
|
|
[1003]: 0
|
|
Polling slave (Ctrl-C to stop) ...
|
|
|
|
The simple testing utility used in the 'demo_rtu.bat' script can be found at
|
|
[3].
|
|
|
|
PROBLEMS
|
|
========
|
|
|
|
In case you can get no communication working make sure that the RS485 line is
|
|
biased correctly. The SAM3S-EK does not populate the RS485 bias resistors by
|
|
default and if you have a RS485 master which does not bias the lines either
|
|
you will get wrong characters. For this R24 and R30 on the bottom side of the
|
|
evaluation kit of the PCB should be populated.
|
|
|
|
REFERENCES
|
|
==========
|
|
|
|
[0] Atmel SAM3S-EK: http://www.atmel.com/dyn/products/tools_card_v2.asp?tool_id=4678
|
|
[1] WinTech ModScan32: http://www.win-tech.com/html/modscan32.htm
|
|
[2] Modus Poll: http://www.modbustools.com/modbus_poll.asp
|
|
[3] FieldTalk Modpoll: http://www.focus-sw.com/fieldtalk/modpoll.html
|
|
[4] Embedded Solutions: http://www.embedded-solutions.at
|
|
|
|
Version: $Id: README.txt,v 1.1 2010/06/06 13:07:19 wolti Exp $
|